JIANGSU – NanTong DATA CENTRE
LOCATION
- Located in Northwestern side of Shanghai
- Situated at Nantong International Data Centre Zone
- 30 minutes travel time from Shanghai by High Speed Railway ready in 2018
- Lay on “One Hour within-reach Economic Circle” with Shanghai-Hangzhou shuttle and Shanghai-Ningbo shuttle
- 100 Kilometers from Hongqiao Airport
- 150 Kilometers from Pudong
- 60% reduction in operation cost compared to Shanghai
COOLING
- Available for individual direction cooling system or chilled Water cooling System
- Diverse Distributed pipework
- CRAC in N+1 configuration
CONNECTIVITY
- Carrier neutral
- China Telecom and China Unicom Internet Access
- Multi-homed BGP Internet Access
- Congestion-free international gateway
- Various type of network services inclusive of SDH, MSTP, Ethernet and Wavelength
- Optimized Internet Solution for local and overseas connectivity
- Direct Access to Shanghai’s Internet Gateway with dark fiber with bandwidth up to 3,000GB
COMPLIANCE
- ISO 20000:2011 – I.T. Service Management System
- ISO 14001:2004 – Environmental Management Systems
- ISO 9001:2008 – Quality Management Systems
- ISO/IEC 27001:2013 – Information Security Management Systems
LICENSE
- Type II Telecom Infrastructure Services – Domestic Fixed Network Data Transmission
- Type I Telecom Value-Added Services – Domestic Internet VPN
- Type I Telecom Value-Added Services – Internet Data Centre
- Type II Telecom Value-Added Services – Internet Access Service
- International Value-Added Network Services (IVANS) (include Internet Access Service)
BUILDING SPECIFICATION
- DC campus comprised of 5 six-storey en-bloc buildings
- Own & operate 1,200,000+ SQFT (120,000 SQM) purpose-built data centre
- Support 20,000+ standard DC racks
- Tier 3+ standard and upgradable to Tier 4
POWER
- Mains availability of the Data Center Campus Area covering 150 MVA
- Dual city power delivered to campus
- On-site fuel tank supporting 24 hour operation
- PUE achieved up to 1.4
FIRE SUPPRESSION SYSTEM
- Heat and smoke detectors
- FM-200 fire suppression system
- Inert gas suppression system
- Pre-action dry pipe sprinkler or high sensitivity smoke detection early warning (HSSD) on request
SECURITY
- Security booth with 24x7 guards stationed at main gate of DC campus
- Registration Lobby protected with mantrap
- Entrance of hosting area secured by electro-mechanical lock and controlled proximity reader
- Enhanced with two-authentication (with operational bio-metric) for mission critical area or customers’ private cage / suite
MONITORING
- 7x24 NOC monitoring all registered infrastructure devices
- 24 hours a day, 7 days a week
- DCIM solutions monitoring, managing and maintaining the availability of data centres’ physical facilities
- iMon365 allowing different network components to be closely monitored